L_PAGE_HLAVNI_NAVIGACE


Module

GL-C700 – GILD unlimited system controller

 

Central unit for communication bus management in GILD unlimited system. The unit enables setting of access rights, security and fire signalization and logic function definition. History of all system events is stored in internal memory of the unit. The unit is also equipped with Ethernet interface for control via computer and or internet.

 

 

 

Specification:

Power supply voltage: 230V AC
Fuse: replaceable melt fuse T630mA
Power input: 16VA
Work temperature: - 10°C to +50°C
Casing: metal cover 390 x 290 x 85 
Installation: on the wall

Dedicated backed-up power supply (accumulator purchased separately)
Power output to communication bus 12V/5 A 
4x programmable relay
Real time circuit
Event memory

GL-AL20 - Access unit

Bus unit for control of inputs based on authorization. Two EDK2 type readers can be connected to the unit for control of doorlocks. One of the readers can be replaced by energy saver EHS3. After reading the card code or fingerprint, the relay connects based on authorization. The unit is connected onto communication bus of the GILD unlimited system.

 

 

 

Specification:

Power supply voltage: 12V DC from communication or external bus
Power intake: 30mA without connected readers
Work temperature: -25°C to + 50°C
Casing: plastic casing 130x 80 x 34 
Installation: on the wall

Up to 2 independent readers for two independent one-way entry points or one both-sided one
Door contact input
Leaving button input

GL-ER81 - Input and output unit

Bus unit for input and output line expansion for both GILD Multi and GILD unlimited systems. It is possible to connect any switch elements to input lines, such as motion or smoke detectors. The output lines can be used for any potential-less switching. It is connected to communication bus.

 

 

 

Specification:

Power supply voltage: 12V DC from communication or external bus
Power outtake:
max. 50mA
Inputs: 0-35 V AC/DC
Outputs: 100V/2A for each relay contact
Work temperature: -25°C to + 50°C
Casing: plastic casing 200x 142 x 42 
Installation: on the wall

8x galvanically separated input lines
8x switch relay
Logical functions between inputs and outputs definition

GILD system features

  • The complex system
  • Independent of actual control items design
  • Usable in both newly built and reconstructed buildings
  • Easy installation and configuration
  • All housing functions under central management
  • High rate of return due to energy savings
  • Original Czech product

Pressentation of GILD system

↑ up